配電裝置

Hawke鎧裝防爆格蘭(501/453/RAC系列

2024-02-21 10:41  瀏覽:362113
搜礦價:
面議
品牌:
Hawke
制造商:
Hawke
適用環境:
其他行業
安標證號:
無需辦證
起訂:
20 只
供貨總量:
500 只
運費承擔:
賣家承擔
所在地:
上海 金山區
有效期至:
長期有效
  • 商品詳情
  • 評價詳情(0)
  • 交易記錄()
 Hawke防爆格蘭代理商:上海頤品自動化科技有限公司 

關鍵詞:Hawke防爆格蘭,Hawke防爆葛蘭,Hawke防爆填料函,Hawke防爆密封接頭

Hawke非鎧防爆格蘭,Hawke鎧裝防爆格蘭,Hawke防爆變徑,Hawke防爆呼吸閥堵頭

Hawke 501/453/RAC Cabel gland

Hawke鎧裝防爆格蘭(501/453/RAC系列)

Hawke代理商:上海頤品自動化科技有限公司

 

Hazardous Area Cable Glands from Hawke

Hawke 501/453/RAC cable glands are suitable for use with single wire armour ‘W’, wire braid ‘X’ and steel tape armour ‘Z’ elastomer and plastic insulated cables.

Hawke 501/453/RAC cable glands are dual certified Exd and Exe and suitable for installation in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC, 3.2-91.6mm outside cable diameters.

When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box.

♦ Exdb IIC Gb, Exeb IIC Gb, Extb IIIC, Db Aromoured Cables ATEX & IECEx Cable Gland.

Hawke 501/453/RAC cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas.

  • Flameproof AExd IIC Gb,

  • Increased Safety AExe IIC Gb

  • Dust AExtD Zone 21

  • Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx

HAWKE 501/453/RAC CABLE GLAND TECHNICAL SPECIFICATION

  1. Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exeb IIC Gb, Extb IIIC Db

  2. Certificate No’s  – baseefa06ATEX0056X and IECEx BAS 06.0013X

  3. Cable Gland Zone Location – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC

  4. Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31

  5. Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X

  6. Deluge Protection – DTS01

  7. Operating Temperature Range  -60°C to +100°C

CABLE GLAND SELECtION TABLE FOR HAWKE 501/453/RAC

Hawke Size Ref. Entry Thread Size

Thread

Length

‘H’

Cable Acceptance Details ‘G’ Compressed Length Hexagon Dimensions
Inner Sheath ‘A’ Outer Sheath ‘B’ ‘C’ Armour/Braid
Standard Seal Alternative Seal (S)
Metric NPT *
Standard Option Min. Max. Min. Max. Min. Max. Orientation 1 Orientation 2 Across Flats Across Corners
Os M20 ‡ ½” 15 3.0 8.0 5.5 12.0 0.8 / 1.25 0 / 0.8 52.0 24.0 26.5
O M20 ‡ ½” 15 6.5 11.9 9.5 16.0 0.8 / 1.25 0 / 0.8 52.0 24.0 26.5
A M20 ¾” ½” 15 10.0 14.3 9.0 13.4 12.5 20.5 0.8 / 1.25 0 / 0.8 53.0 30.0 32.5
B M25 1″ ¾” 15 13.0 20.2 9.5 15.4 16.9 26.0 1.25 / 1.6 0 / 0.7 59.5 36.0 39.5
C M32 1¼” 1″ 15 19.5 26.5 15.5 21.2 22.0 33.0 1.6 / 2.0 0 / 0.7 64.0 46.0 50.5
C2 M40 1½” 1¼” 15 25.0 32.5 22.0 28.0 28.0 41.0 1.6 / 2.0 0 / 0.7 68.3 55.0 60.6
D M50 2″ 1½” 15 31.5 44.4/42.3 † 27.5 34.8 36.0 52.6 1.8 / 2.5 0 / 1.0 79.0 65.0 70.8
E M63 2½” 2″ 15 42.5 56.3/54.3 † 39.0 46.5 46.0 65.3 1.8 / 2.5 0 / 1.0 78.4 80.0 88.0
F M75 3″ 2½” 15 54.5 68.2/65.3 † 49.5 58.3 57.0 78.0 1.8 / 2.5 0 / 1.0 83.7 95.0 104.0
G M80 3½” 20 67.0 73.0 75.0 89.5 2.0 / 3.5 0 / 1.0 95.6 106.4 115.0
H M90 3½” 20 67.0 77.6 75.0 89.5 2.0 / 3.5 0 / 1.0 95.6 115.0 130.0
J M100 4″ 20 77.0 91.6 88.0 104.5 2.5 / 4.0 0 / 1.0 95.6 127.0 142.0

All dimensions in millimetres (except*).
Os – F size metric entry threads are 1.5mm pitch as standard. For G size Cable Glands and above, a 2mm pitch is supplied as standard (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering.
† Smaller value is applicable when selecting reduced NPT entry option.
Sizes Os and O are available with an M16 thread size. For O size with an M16 thread, the maximum cable inner sheath diameter is 10.9mm.

CABLE GLAND MATERIAL & FINISH

Hawke 501/453/RAC cable glands are manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.

PREPARING CABLE & GLAND FOR INSTALLING HAWKE 501/453/RAC
CABLE PREPARATION

Strip Cable to suit equipment as shown above and expose the armour/braid ‘I’.

‘I’ = 20mm for cable gland sizes Os to C ‘I’ = 25mm for cable gland sizes C2 to F ‘II’ = to suit equipment. If required, fit shroud.

CABLE GLAND PREPARATION

Push the cable through the armour spigot (4). Spread armour/braid over the armour spigot (4) until the end of the armour/braid is up against the shoulder of the armour cone. Position the armour clamping ring (3).

Remove the inner seal (5) from the entry (6). Place the entry (6) over the armour spigot (4). Move the sub-assembly (1) and (2) up to meet the entry (6). Note: If the equipment has a threaded entry, it may be advisable to screw the entry component into the equipment to prevent twisting of the cable after step D

 

Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.

Flameproof Exdb and Increased Safety Exeb (Dust Extb) Dual Certified glands from Hawke include – for further information review the product pages or contact us to discuss your cable gland requirements.

  • 501/421 Cable Gland Unarmoured   – outer cable sheath cable sealing

  • 501/423 Cable Gland Unarmoured – flameproof seal to inner/outer cable sheath with IP seal on the outer sheath

  • 501/453 Universal Cable Gland Wire Armoured Baided Steel Tape Armoured – indoor/outdoor hazardous areas

  • ICG 623 Barrier Gland Unarmoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

  • ICG 653 Barrier Gland Armoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

Hawke防爆格蘭(Hawke Cable Glands-上海頤品自動化)

Hazardous Area Cable Glands-ATEX IECEX,Exe,Exd Group II

Hawke防爆格蘭代理商:上海頤品自動化科技有限公司

關鍵詞:Hawke防爆格蘭,Hawke防爆變徑,Hawke防爆堵頭,

Hawke防爆呼吸閥,Hawke防爆接線盒,Hawke防爆控制箱

Hawke防爆格蘭等產品規格書及相關證書-請咨詢上海頤品自動化科技有限公司

 

 

 Hawke防爆格蘭代理商:上海頤品自動化科技有限公司 

關鍵詞:Hawke防爆格蘭,Hawke防爆葛蘭,Hawke防爆填料函,Hawke防爆密封接頭

Hawke非鎧防爆格蘭,Hawke鎧裝防爆格蘭,Hawke防爆變徑,Hawke防爆呼吸閥堵頭

Hawke 501/453/RAC Cabel gland

Hawke鎧裝防爆格蘭(501/453/RAC系列)

Hawke代理商:上海頤品自動化科技有限公司

 

Hazardous Area Cable Glands from Hawke

Hawke 501/453/RAC cable glands are suitable for use with single wire armour ‘W’, wire braid ‘X’ and steel tape armour ‘Z’ elastomer and plastic insulated cables.

Hawke 501/453/RAC cable glands are dual certified Exd and Exe and suitable for installation in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC, 3.2-91.6mm outside cable diameters.

When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box.

♦ Exdb IIC Gb, Exeb IIC Gb, Extb IIIC, Db Aromoured Cables ATEX & IECEx Cable Gland.

Hawke 501/453/RAC cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas.

  • Flameproof AExd IIC Gb,

  • Increased Safety AExe IIC Gb

  • Dust AExtD Zone 21

  • Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx

HAWKE 501/453/RAC CABLE GLAND TECHNICAL SPECIFICATION

  1. Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exeb IIC Gb, Extb IIIC Db

  2. Certificate No’s  – baseefa06ATEX0056X and IECEx BAS 06.0013X

  3. Cable Gland Zone Location – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC

  4. Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31

  5. Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X

  6. Deluge Protection – DTS01

  7. Operating Temperature Range  -60°C to +100°C

CABLE GLAND SELECtION TABLE FOR HAWKE 501/453/RAC

Hawke Size Ref. Entry Thread Size

Thread

Length

‘H’

Cable Acceptance Details ‘G’ Compressed Length Hexagon Dimensions
Inner Sheath ‘A’ Outer Sheath ‘B’ ‘C’ Armour/Braid
Standard Seal Alternative Seal (S)
Metric NPT *
Standard Option Min. Max. Min. Max. Min. Max. Orientation 1 Orientation 2 Across Flats Across Corners
Os M20 ‡ ½” 15 3.0 8.0 5.5 12.0 0.8 / 1.25 0 / 0.8 52.0 24.0 26.5
O M20 ‡ ½” 15 6.5 11.9 9.5 16.0 0.8 / 1.25 0 / 0.8 52.0 24.0 26.5
A M20 ¾” ½” 15 10.0 14.3 9.0 13.4 12.5 20.5 0.8 / 1.25 0 / 0.8 53.0 30.0 32.5
B M25 1″ ¾” 15 13.0 20.2 9.5 15.4 16.9 26.0 1.25 / 1.6 0 / 0.7 59.5 36.0 39.5
C M32 1¼” 1″ 15 19.5 26.5 15.5 21.2 22.0 33.0 1.6 / 2.0 0 / 0.7 64.0 46.0 50.5
C2 M40 1½” 1¼” 15 25.0 32.5 22.0 28.0 28.0 41.0 1.6 / 2.0 0 / 0.7 68.3 55.0 60.6
D M50 2″ 1½” 15 31.5 44.4/42.3 † 27.5 34.8 36.0 52.6 1.8 / 2.5 0 / 1.0 79.0 65.0 70.8
E M63 2½” 2″ 15 42.5 56.3/54.3 † 39.0 46.5 46.0 65.3 1.8 / 2.5 0 / 1.0 78.4 80.0 88.0
F M75 3″ 2½” 15 54.5 68.2/65.3 † 49.5 58.3 57.0 78.0 1.8 / 2.5 0 / 1.0 83.7 95.0 104.0
G M80 3½” 20 67.0 73.0 75.0 89.5 2.0 / 3.5 0 / 1.0 95.6 106.4 115.0
H M90 3½” 20 67.0 77.6 75.0 89.5 2.0 / 3.5 0 / 1.0 95.6 115.0 130.0
J M100 4″ 20 77.0 91.6 88.0 104.5 2.5 / 4.0 0 / 1.0 95.6 127.0 142.0

All dimensions in millimetres (except*).
Os – F size metric entry threads are 1.5mm pitch as standard. For G size Cable Glands and above, a 2mm pitch is supplied as standard (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering.
† Smaller value is applicable when selecting reduced NPT entry option.
Sizes Os and O are available with an M16 thread size. For O size with an M16 thread, the maximum cable inner sheath diameter is 10.9mm.

CABLE GLAND MATERIAL & FINISH

Hawke 501/453/RAC cable glands are manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.

PREPARING CABLE & GLAND FOR INSTALLING HAWKE 501/453/RAC
CABLE PREPARATION

Strip Cable to suit equipment as shown above and expose the armour/braid ‘I’.

‘I’ = 20mm for cable gland sizes Os to C ‘I’ = 25mm for cable gland sizes C2 to F ‘II’ = to suit equipment. If required, fit shroud.

CABLE GLAND PREPARATION

Push the cable through the armour spigot (4). Spread armour/braid over the armour spigot (4) until the end of the armour/braid is up against the shoulder of the armour cone. Position the armour clamping ring (3).

Remove the inner seal (5) from the entry (6). Place the entry (6) over the armour spigot (4). Move the sub-assembly (1) and (2) up to meet the entry (6). Note: If the equipment has a threaded entry, it may be advisable to screw the entry component into the equipment to prevent twisting of the cable after step D

 

Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.

Flameproof Exdb and Increased Safety Exeb (Dust Extb) Dual Certified glands from Hawke include – for further information review the product pages or contact us to discuss your cable gland requirements.

  • 501/421 Cable Gland Unarmoured   – outer cable sheath cable sealing

  • 501/423 Cable Gland Unarmoured – flameproof seal to inner/outer cable sheath with IP seal on the outer sheath

  • 501/453 Universal Cable Gland Wire Armoured Baided Steel Tape Armoured – indoor/outdoor hazardous areas

  • ICG 623 Barrier Gland Unarmoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

  • ICG 653 Barrier Gland Armoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

Hawke防爆格蘭(Hawke Cable Glands-上海頤品自動化)

Hazardous Area Cable Glands-ATEX IECEX,Exe,Exd Group II

Hawke防爆格蘭代理商:上海頤品自動化科技有限公司

關鍵詞:Hawke防爆格蘭,Hawke防爆變徑,Hawke防爆堵頭,

Hawke防爆呼吸閥,Hawke防爆接線盒,Hawke防爆控制箱

Hawke防爆格蘭等產品規格書及相關證書-請咨詢上海頤品自動化科技有限公司

 

 

為您挑選